machine,restarted,preventing,position,padlocked,inserted

 


AM Lock-out Clip

AM Lock-out Clip
AML
Once inserted into the head and padlocked in position, it blocks the handle entry preventing the door being closed and the machine from being restarted.

Images

AM Lock-out Clip




Safety Data

Standards 2006/95/EC (Low voltage directive), 2006/42/EC (The machinery directive), 2004/108/EC (The EMC Directive), EN60947-5-1:2004, EN61010-1:2001, EN1088:1996, EN12100-1:2003, EN12100-2:2003, EN13849-1: 2006, EN62061:2006, EN61000-6-2:2005, EN61000-6-3:2007
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (31250,0 years)
CCF 90%
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 3,65E-09

* use the "Functional Safety Calculator" to calculate values with varying conditions
** amGard modules need to be constructed as a complete assembly to reach stated values