circuits,position,combination,latching,operated,operating,restart,function

 


Start / Re-Start Key Switch

Start / Re-Start Key Switch
SC
  • Start restart key switch, operating on safety circuits
  • Uses 1 NO and 1 NC
  • For safety relay re-set
  • With Ronis key operated reset function
  • Latching - stay in each switch position

Cannot be used in combination with any other unit that acts on the safety circuits



TUV (EU+USA+Canada)

I/O & Safety Circuits

Images

Start / Re-Start Key Switch
Start / Re-Start Key Switch




Safety Data

Standards EN 60947-1:2007 (Low-voltage switchgear and control gear), EN60975-5-1:2004, EN62061:2005, EN/ISO13849-1:2008, EN50178:1997, EN60204-1:2006, EN50295:1999, GS-ET-19:04/2004
Certifications CE marked for all applicable directives
Category Cat. 4, PLe (EN/ISO 13849-1) and SIL3 (EN/IEC 62061)
Functional safety data* B10d 5.000.000
MTTfd High > 385 years (590 years)
CCF  
DC High 99% (with correct monitoring of both channels and including the opposite-mode monitoring switch)
PFHd [1/h] 5,90E-10

* eGard modules need to be constructed as a complete assembly to reach stated values